Drop by!
LEDCity AG
Werdstrasse 21
CH- 8004 Zürich
Follow us!
Discover the energy calculator now.

Who would you like to send your enquiry to?

Would you like personalised advice?

catrina klee ledcity
julian wiederkehr ledcity

We would also be happy to advise you personally to find the ideal lighting solution for your application!
We look forward to hearing from you!

Make an appointment

Kontakt Overlay (EN)

This field is for validation purposes and should be left unchanged.

Would you like personalised advice?

catrina klee ledcity
julian wiederkehr ledcity

Your enquiry cannot be resolved?
Our customer service is there for you from Monday to Friday: 08:00am - 05:30pm

Make an appointment

Kontakt Overlay (EN)

This field is for validation purposes and should be left unchanged.

Request your quote now.

catrina klee ledcity
julian wiederkehr ledcity

We would also be happy to advise you personally to find the ideal lighting solution for your application!
We look forward to hearing from you.

Make an appointment

SA Tube.

Our “Semi-Autonomous” LED tubes change the lighting intensity and duration automatically. The savings potential is significantly increased by high lighting efficiency and a shorter operating time. Thanks to an integrated radar and light sensor, the control system takes decisions away from people and adjusts the light to the actual requirement over a small area. This reduces energy consumption by around 60 per cent compared to a conventional system with motion detectors. In addition, the run-on time and basic lighting can be easily set on the product to optimise energy savings and offer the greatest possible convenience for every application. Due to the reduced operating time and high quality, the service life is also 1.5 times longer than that of conventional LED tubes.

 

Downloads.

Here you will find data sheets, instructions and much more to get more information about the product.

SA T5 - Data sheet
SA T8 - Data sheet
SA - Installation instructions
SA - Energy Labels
SA - Light Data

Technical specifications.

Input voltage
100 - 240 VAC
Battery operation
190 - 240 VDC
Operating frequency
50 - 60 Hz
Power factor
0.94
Voltage peak strength
300 VACrms
Compatible with ECG
No
Design
T8
Pedestal
G5
Rotatable base
Yes
Material
Al / PC / PE
Cooling system
Passive / 235 W/ (mK)
Cover
Satinised
Colour temperature
3000 - 6000 K
Colour rendering index
80 - 95
Colour consistency (MacAdam)
2
Flicker measurand (Pst LM)
0.01
Strobe effects (SVM)
0.01
UGR (4H/8H; 70/50/20) (per/par)
<27.8/ <25
System efficiency
143 lm/W
Energy class
D
Service life
70'000 h
IP protection class
IP20
Protection class
II
LED risk group
RG0
Operating temperature
-20 °C .. 45 °C
Storage temperature
-20 °C .. 70 °C
Operating & storage humidity
10-80 % rH
Motion detector technology
Radar (HF)
Motion detector - performance
< 1mW
Motion detector - Frequency
5.80GHz
Motion detector - Distance
< 5m
Detection distance adjustable
No
Follow-up time settings
1s - 30 min
Gradual light start
Yes
Basic light function
Yes
Basic light settings
0 - 100% /10% step
Daylight control
Yes
Group formation
No
Schwarmintelligenz
No
Remote access
No
Browse further.

Further products.

SA Circular
SA Circular
Non-Autonomous Tube
Non-Autonomous Tube

Calculate your energy saving potential.

Find out how much money you can save with our intelligent lighting solution.
Determine your potential savings
case slider chedi
retrofit-ledcity
Simple Retrofit
increased value amortization-ledcity
High energy savigns
roi-amortisation-ledcity
Quick amortisation
Hotel Chedi Andermatt.

This is how it could look like.

In the hotel "The Chedi" in Switzerland, over 1000 sensor-controlled LEDCity tubes save 78% energy compared to the previous lighting with motion detectors through automatic regulation of light intensity and duration in corridors, parking, and ancillary rooms.

To the case
case-slider-zhdk-ledcity
increased value amortization-ledcity
Increase in value
energy report-ledcity
90% less energy consumption
co2-reduction-ledcity
Less CO2 consumption
Zurich University of the Arts.

This is how it could look like.

The ZHdK building on the Toni site in Zurich has a large number of fluorescent tubes for lighting: previously exclusively conventional FL tubes, now also a considerable number of intelligent, sensor-controlled LEDCity tubes. This conversion currently saves up to 92% energy.

To the case
ledcity dolder grand parkhaus spirale CMD px
increased value amortization-ledcity
Cost reduction for maintenance
energy-ledcity
High energy-efficiency
roi-amortisation-ledcity
Subventions for the conversion
The Dolder Grand.

This is how it could look like.

The hotel aimed to reduce energy consumption and, in collaboration with LEDCity, replaced a significant portion of the linear lighting. This resulted in an annual saving equivalent to the energy consumption of over 700 average households.

To the case

Request your quote now.

portrait patrik kuster led city CMD
catrina klee ledcity
julian wiederkehr ledcity

We would also be happy to advise you personally to find the ideal lighting solution for your application!
We look forward to hearing from you!

Make an appointment