Schau vorbei!
LEDCity AG
Werdstrasse 21
CH- 8004 Zürich
Folge uns!
Discover the energy calculator now.

Who would you like to send your enquiry to?

Would you like personalised advice?

catrina klee ledcity
julian wiederkehr ledcity

We would also be happy to advise you personally to find the ideal lighting solution for your application!
We look forward to hearing from you!

Make an appointment

Kontakt Overlay (EN)

This field is for validation purposes and should be left unchanged.

Would you like personalised advice?

catrina klee ledcity
julian wiederkehr ledcity

Your enquiry cannot be resolved?
Our customer service is there for you from Monday to Friday: 08:00am - 05:30pm

Make an appointment

Kontakt Overlay (EN)

This field is for validation purposes and should be left unchanged.

Request your quote now.

catrina klee ledcity
julian wiederkehr ledcity

We would also be happy to advise you personally to find the ideal lighting solution for your application!
We look forward to hearing from you.

Make an appointment

NOMUS Tube.

NOMUS offers an all-in-one solution: we supply the right hardware and software, integrated sensor and control components as well as unique functions such as true swarm intelligence, daylight sensors and remote configuration and maintenance. This enables demand-led lighting that is energy-efficient and extremely flexible while offering a high level of comfort. Our NOMUS Tube enables savings of up to 80% compared to conventional LEDs and has twice the life time. Installation is simple via “Plug & Play” in the existing fixtures.

Downloads.

Here you will find data sheets, instructions and much more to get more information about the product.

NOMUS Tube T5 - Data sheet
NOMUS Tube T8 - Data sheet
NOMUS Tube installation & operating instructions

Technical specifications.

Input voltage
100 - 240 VAC
Battery operation
190 - 240 VDC
Operating frequency
50-60 Hz
Power factor
0.92
Voltage peak strength
300 VACrms
Compatible with ECG
No
Design
T8
Pedestal
G5 / G13
Rotatable base
Yes
Material
Al / PC / PE
Cooling system
Passive / 235 W/(m/
Cover
Satinised
Colour temperature
3000-6000 K
Colour rendering index
80-95
Colour consistency (MacAdam)
3
Flicker measurand (PstLM)
0.03
Strobe effects (SVM)
0.02
UGR (4H/ 8H; 70/50/20) /per/par)
<27.8/ <25
System efficiency
147 lm/W
Energy class
D
Switching cycle stability
> 500'000
Service life
90'000 h
IP protection class
IP20
Protection class
II
LED risk group
RG0
Operating temperature
-20 °C .. 45 °C
Storage temperature
-20 °C .. 70 °C
Operating & storage humidity
10 - 80 % rH
Motion detector technology
Radar (HF)
Motion detector - performance
0.17 - 3.0mW
Motion detector - Frequency
5.80 GHz
Motion detector - Distance
< 4m
Communication technology
Wirepas Mesh
Communication - Performance
2.5 mW
Communication - Frequency
2.4 GHz
Communication - Distance
max. 8-12m
Follow-up time setting
1s - 4h
Gradual light start
Ja
Basic light function
Ja
Basic light setting
0-100% /1% step
Daylight control
Yes
Group formation
Yes
Swarm intelligence
Yes
Remote access
Yes
Browse further.

Further products.

NOMUS Aval
NOMUS Aval
NOMUS Lucid Globe
NOMUS Lucid Globe
NOMUS Sensor Node DALI
NOMUS Sensor Node DALI
NOMUS Wall Switch
NOMUS Wall Switch

Calculate your energy saving potential.

Find out how much money you can save with our intelligent lighting solution.
Determine your potential savings
wohngebäude manegg
increased value amortization-ledcity
Comfort
wifi-iot-ledcity
Individual Configuration
connected network NOMUS-ledcity
Connected Building
ZHil Manegg.

Our cases.

In the new residential development "ZHil," 600 LEDCity light sources were installed in the parking garages, corridors, staircases, and cellar compartments. In contrast to LED lighting with central motion detectors, NOMUS enables savings of CHF 143,311.

To the case
stampfenbach ledcity
remote-maintenance-ledcity
Remote Maintenance
connected network NOMUS-ledcity
Flexible Settings
energy report-ledcity
Frequent Energy Reports
Parking Stampfenbach.

Our cases.

A public parking in Zurich had its lighting switched on around the clock. Due to rising energy prices, the outdated system was replaced by NOMUS, which impresses with flexibility and comfort, security, and, above all, an 80% energy savings – despite previous LED lighting.

To the case

Request your quote now.

portrait patrik kuster led city CMD
catrina klee ledcity
julian wiederkehr ledcity

We would also be happy to advise you personally to find the optimum lighting solution for your application!
We look forward to hearing from you!

Make an appointment